1. A 3% distortion rate for pure sine wave output;
2. A wide work range of -40°C to +50°C;
3. The work mode for intelligent fan cooling;
4. Support optional CANBUS and RS485 connectivity;
5. Incorrect input connection, high or low voltage, output overload, short circuit, or overheating, etc.;
6. Wireless remote control or wired remote control and so on(optional);
 7. Input voltage and frequency can be selected by DIP S.W;
 8. DC input and AC output are completely isolated;
 9. Suitable for lead acid battery and lithium battery;
| Model | FSA500H | FSA1000H | FSA1200H | FSA1500H | FSA2000H | |
| Output | Continuous Power | 500 Watt | 1000 Watt | 1200 Watt | 1500 Watt | 2000 Watt | 
| Peak Power | 1000 Watt | 2000 Watt | 2400 Watt | 3000 Watt | 4000 Watt | |
| Output Waveform | Pure Sine Wave(Distortion rate≤3%) | |||||
| Output Frequency | 50/60Hz±2% | |||||
| Output Voltage | Default Setting: 230V±5V | Default Setting: 110V±5V | ||||
| Other Voltage: 230V/240V | Other Voltage: 110V/120V | |||||
| Input | Input Voltage | 12VDC | 24VDC | 12VDC | 24VDC | |
| Input Voltage Rate | DC9.5V-15.5V | DC19V-31.5V | DC9.5V-15.5V | DC19V-31.5V | ||
| Low Voltage Alarm | DC10.5V±0.5V | DC21V±0.5V | DC10.5V±0.5V | DC21V±0.5V | ||
| Low Voltage Protection | DC9.5±0.5V | DC19±0.5V | DC9.5±0.5V | DC19±0.5V | ||
| Low Voltage Recovery | DC12V±0.5V | DC24.5V±0.5V | DC12V±0.5V | DC24.5V±0.5V | ||
| Over Voltage Recovery | DC15V±0.5V | DC30.5V±0.5V | DC15V±0.5V | DC30.5V±0.5V | ||
| Over Voltage Protection | DC15.5V±0.5V | DC31.5V±0.5V | DC15.5V±0.5V | DC31.5V±0.5V | ||
| Output Protection | Over Temperature Protection | 70℃±5℃ | ||||
| Protection mode: re-start after buzzer continuously alarm 5 sounds with turning off the output voltage and temperature lower than 65 degrees. | ||||||
| Output Short Circuit | Protection mode: restore the output after turn off the output voltage and exclude the possibility of short circuit. | |||||
| Overload Protection | The load at 105-115% lasts for 180 seconds, and at 115-150% for 10 seconds | |||||
| Protection mode: restore the output after the buzzer continuous alarm with turned off output and lower load | ||||||
| Conversion Efficiency | 92% (Full load) | |||||
| Wireless remote control | 50m Barrier-free control inverter | |||||
| RS-485 | RS-485 communication | |||||
| CANBUS | CANBUS communication | |||||
| TTL | TTL communication | |||||
| No-load Current | ≤0.3A (DC12V) | |||||
| Working Temperature | 〔-20℃〕TO〔+50℃〕 | |||||
| Working Humidity | 20-90%RH Non-condensing | |||||
| Storage Temperature | 〔-30℃〕TO〔+70℃〕 | |||||
| Cooling Mode | Intelligent temperature control air cooling, or fan start-up when temperature > 100W | |||||
| Certificate | CE、FCC and ROHS | |||||
 
		    
			 
		    
			