Igbt Type Power Factor Compensator 220v Static Var Generator 3 Phase 3 Wire/4 Wire 10kvar 20kvar

Short Description:

Noker three phase 200V mini static var generator SVG adopt the three level technology, used for three phase load unbalance, power factor correction, power harmonics filtering, effectively reduce line loss, and prolonging the life of power equipment.

Noker three phase 200V mini Static Var Generator is suitable to form a hybrid Var compensation(HVC) solution with capacitors and reactors Due to its high performance and most cost effective, it is widely used.


Product Detail

Product Tags

Features

Svg static var generator checks the load current through the external CT and performs computing through the external DSP to analyze the reactive content of the load current. After that, it controls the PWM signal generator based on the settings to send control signals to the internal IGBT. In this way, it generates reactive compensation current to implement dynamic reactive power compensation.

1.Three-level inverter technology, high energy efficiency,
2.Integration of load balancing, power factor compensation, harmonics filtering into one module.
3.Built-in RS485 interface to control intelligent capacitor.

4.High-speed response, Overall response time <7.8ms
5.Load balancing and unloading of neutral wires
6.Flexibility and modularity.

svg_static_var_generator

Specification

220V SVG checks the load current through the external CT and performs computing through the external DSP to analyze the reactive content of the load current. After that, it controls the PWM signal generator based on the settings to send control signals to the internal IGBT. In this way, it generates reactive compensation current to implement dynamic reactive power compensation.

Network voltage(V) 200/400 690
Network voltage range -20%--+20%
Network frequency(Hz)

50/60(-10%--+10%)

Scope of compensation

Capacitive and inductive continuously adjustable

CT mounting method

Open or closed loop(recommend in parallel operation)

CT mounting position

Grid side/load side

Response time

10ms or less

Connection method

3-wire/4-wire

Overload capacity

110%Continuous operation, 120%-1min

Circuit topology

Three-level topology

Switching frequency(khz)

20kHz

Redundancy

Any unit can become a stand-alone unit

Unbalance governance

Available

SVC

Available

Display

No screen/4.3/7 inch screen(optional)

Capacity(kVar) 25、50、75、100、150
50、100
Harmonic range

2nd to 50th order 

Communication port

RS485

CAN protocol, RJ45 interface, for communication between modules

Noise level

<56dB Max to <69dB(depending on module or load conditions)

Mounting type Cabinet Wall-mounted, rack-mounted, cabinet
Altitude

Derating usage>1500m

Temperature

Operating temperature: -45℃--55℃,  derating usage above 55℃

Storage temperature: -45℃--70℃

Humidity

5%--95%RH, non-condensing

Protection class

IP20

Design/approvals

EN 62477-1(2012), EN 61439-1(2011)

EMC

EN/IEC 61000-6-4, Class A

Certification

CE, CQC

Product display

noker_active_harmonic_filters_mainboard
noker_ahf_pcb_board

The 220v mini static var generator adopts the hardware structure of DSP+FPGA, and the components are of high quality. Thermal simulation technology is used for thermal design of the system, and multi-layer PCB circuit board design ensures reliable isolation of high and low pressure, which provides guarantee for system safety.

Application

filter cabinet
Noker power filter cabinet

Where there is a low-voltage transformer installed and next to large electrical equipment should be equipped with reactive power compensation devices svg static var generator(this is the provisions of the national power department), especially those with low power factor industrial mines, enterprises, residential areas must be installed. Large asynchronous motors, transformers, welding machines, punches, lathes, air compressors, presses, cranes, smelting, steel rolling, aluminum rolling, large switches, electric irrigation equipment, electric locomotives, etc. In addition to incandescent lighting in residential areas, air conditioning, refrigerators, etc., are also reactive power consumption objects that can not be ignored. The rural electricity situation is relatively bad, most areas lack of power supply, voltage fluctuation is very large, power factor is especially low, installing compensation equipment is an effective measure to improve the power supply situation and improve the utilization rate of electric energy. 220v mini static var generator must the most ideal reactive power compensation device.

1.All types of industrial installations
2.Equipment using variable speed drive (VSD)
3.arcing equipment: electric arc furnace (EAF), ladle furnace (LF), and arc welding machine
4.Switching power supply: computer, TV, photocopiers, printer, air conditioner, PLC
5.UPS system
6.Data center
7.Medical equipment: MRI scanner, CT scanner, X-ray machine, and linear accelerator
8.Lighting equipment: LED, fluorescent lamp, mercury vapor lamp, sodium vapor lamp, and an ultraviolet lamp
9.Solar inverter and wind turbine generators

Customer service

1. ODM/OEM service is offered.

2. Quick order confirmation.

3. Fast delivery time.

4. Convenient payment term.

At present, the company is vigorously expanding overseas markets and global layout. We are committed to becoming one of the top ten export enterprises in China’s electrical automatic product, serving the world with high-quality products and achieving a win-win situation with more customers.

Noker SERVICE
Freight

  • Previous:
  • Next: